rtc: ds1307: fix RX8130 wakeup alarm WADA bit for day-of-month mode
The RX8130 wakeup alarm never fired when set via /sys/class/rtc/rtc0/wakealarm. The root cause is that the WADA bit (bit 3) in the Extension register (0x1c) was never set before programming the alarm registers. Per the RX8130 datasheet: WADA=0 - Week alarm: register 0x19 is compared against day-of-week WADA=1 - Day alarm: register 0x19 is compared against day-of-month rx8130_set_alarm() always writes a BCD day-of-month value to alarm register 0x19, so WADA must be 1. With WADA=0 the hardware matched the day-of-month value (e.g. 15) as a day-of-week index, which is always out of range (valid weekdays are 0-6), so the alarm interrupt was never asserted. Fix by setting the WADA bit in rx8130_set_alarm() before writing the Extension register back to the device. This is consistent with rx8130_read_alarm(), which decodes the same register under the same assumption (24-hour and day-of-month mode). Signed-off-by: Robert Leussler <robert.leussler@leica-geosystems.com> Link: https://patch.msgid.link/20260721081907.3518648-1-robert.leussler@leica-geosystems.com Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
Diffstat (limited to 'tools/perf/scripts/python/stackcollapse.py')
0 files changed, 0 insertions, 0 deletions