diff options
| author | Jose VillaseƱor Montfort <pepemontfort@gmail.com> | 2026-07-28 14:13:09 -0600 |
|---|---|---|
| committer | Jiri Kosina <jkosina@suse.com> | 2026-08-03 20:38:09 +0200 |
| commit | d07644524b6511b622ee7b0e2e68c9ee43d522a4 (patch) | |
| tree | 3649bb26bb354f0fec7df97cfa52ffd5ae75f3ef /tools/perf/scripts/python/bin | |
| parent | cdf826a94e0fef8dfc707967e8efee5571ca0f37 (diff) | |
HID: input: read battery capacity from its actual report offset
hidinput_query_battery_capacity() assumes the state-of-charge value is
the first byte following the report ID (buf[1]) and ignores where the
battery field actually sits within the report.
An Apple Magic Trackpad 2 precedes the AbsoluteStateOfCharge byte with a
byte of status flags in its battery reports, so this query returns the
flags byte instead of the charge level.
The device happens to make that easy to observe, because it exposes the
same cell twice: its report descriptor declares AbsoluteStateOfCharge in
two reports (0x90 and 0x9b), so hidinput_setup_battery() registers two
power supplies. Only the first one is refreshed by hid-magicmouse -- it
uses hid_get_battery(), which returns the first battery of the list --
and that refresh goes through the report event path, which parses the
field correctly. Nothing ever reports the second one, so every read of
its capacity takes the query path above. On a USB-C Magic Trackpad over
USB, on an unpatched 7.1.5:
hid-<serial>-battery-144 = 100% (Charging) <- report event path
hid-<serial>-battery-155 = 3% (Discharging) <- query path
Both are the same physical battery. A raw HIDIOCGINPUT of the two
reports at that same moment:
report 0x90 -> [90 03 64]
report 0x9b -> [9b 03 64 64 00 00 10 00 00 00 00 00 00 00]
^flags ^SoC = 0x64 = 100%
The device answers correctly in both cases; only the offset the kernel
reads the capacity from is wrong. 0x03 is the flags byte (present,
charging), reported as "3%".
Bluetooth takes the same query path for its capacity, where the trackpad
reported a bogus near-constant ~4% -- 0b100, the FullyCharged flag --
regardless of the real charge.
Store the battery field's offset within the report at setup time and use
it when querying, so the capacity is read from its real position. The
report event path already parses the field correctly through the HID
core; only the explicit GET_REPORT query was wrong.
Devices whose capacity field is the first field in the report have a
report_offset of 0 and are unaffected (buf[1 + 0] == buf[1]).
Fixes: 581c4484769e ("HID: input: map digitizer battery usage")
Cc: stable@vger.kernel.org
Signed-off-by: Jose VillaseƱor Montfort <pepemontfort@gmail.com>
Reviewed-by: Alec Hall <signshop.alec@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
Diffstat (limited to 'tools/perf/scripts/python/bin')
0 files changed, 0 insertions, 0 deletions