diff options
| author | Mert Seftali <mertsftl@gmail.com> | 2026-07-10 10:36:23 +0200 |
|---|---|---|
| committer | Jonathan Cameron <jonathan.cameron@oss.qualcomm.com> | 2026-07-12 03:10:06 +0100 |
| commit | aa58ecc73466d0cb8c418de98e2225490bf600e3 (patch) | |
| tree | 22b852ae51d024f1379e246c59202d601abc8a1b /tools/perf/scripts/python/bin/stackcollapse-record | |
| parent | daf79105f9b08a3f2cb205a32bf8e57c936095f4 (diff) | |
iio: accel: dmard09: Implement IIO_CHAN_INFO_SCALE
Reading the in_accel_scale attribute on the DMARD09 has always returned
-EINVAL: the channels advertise scale via info_mask_shared_by_type so the
IIO core exposes the attribute, but dmard09_read_raw() only handles
IIO_CHAN_INFO_RAW, so a SCALE read falls through to 'default: return
-EINVAL':
$ cat .../iio:deviceX/in_accel_scale
cat: in_accel_scale: Invalid argument
leaving userspace with raw counts it cannot convert to m/s^2.
The driver was written from a vendor source [1] without a datasheet, and
the scale was declared but never implemented. The vendor source carries
the sensitivity: its conversion is
acc = raw * GRAVITY_EARTH_1000 / sensitivity (then / 1000 -> m/s^2)
with sensitivity = 32 and GRAVITY_EARTH_1000 = 9807 ("about
(9.80665)*1000"), i.e. 32 counts correspond to 1 g.
That sensitivity applies to the value this driver already reports as raw:
the vendor reduces each 16-bit sample to a signed 9-bit value, and the
preparation in dmard09_read_raw() yields the same value. It is
self-consistent: 256 counts / 32 = 8 g full scale, matching the +/-8g
range.
Implement the scale derived from that sensitivity using standard gravity:
scale = 9.80665 / 32 = 0.3064578125 m/s^2 per LSB
Link: https://github.com/minstrelsy/mediatek/blob/1f49d8c87b839651bc89afc870277e8e0f2e2d55/custom/common/kernel/accelerometer/dmard09/dmard09.c [1]
Fixes: a4fa6509dda4 ("iio: accel: add support for the Domintech DMARD09 3-axis accelerometer")
Signed-off-by: Mert Seftali <mertsftl@gmail.com>
Reviewed-by: Joshua Crofts <joshua.crofts1@gmail.com>
Signed-off-by: Jonathan Cameron <jonathan.cameron@oss.qualcomm.com>
Diffstat (limited to 'tools/perf/scripts/python/bin/stackcollapse-record')