summaryrefslogtreecommitdiff
path: root/tools/lib/python
diff options
context:
space:
mode:
authorCan Guo <can.guo@oss.qualcomm.com>2026-03-05 03:08:56 -0800
committerMartin K. Petersen <martin.petersen@oracle.com>2026-03-07 11:04:35 -0500
commitb5e21a29fe9459aef1e6b20b9315e8f3690f8f31 (patch)
tree9a0fae43552102c9838159987bdcb89644d2d66d /tools/lib/python
parent7a3aff163c77159d262217382ec0e9c06c847b46 (diff)
scsi: ufs: core: Add support to notify userspace of UniPro QoS events
The UniPro stack manages to repair many potential Link problems without the need to notify the Application Layer. Repair mechanisms of the stack include L2 re-transmission and successful handling of PA_INIT.req. Nevertheless, any successful repair sequence requires Link bandwidth that is no longer vailable for the Application. Therefore, it may be useful for an Application to understand how often such repair attempts are made. The DME implements Quality of Service monitoring using a simple counting scheme, counting error events and comparing them against the number of correctly received or transmitted bytes. When the error counter exceeds a programmed threshold before the byte counter overflows, a DME_QoS.ind is issued to the Application and both counters are reset. When the byte counter overflows before the error counter has reached the programmed threshold, both counters are reset without triggering a DME_QoS.ind. The DME provides Link quality monitoring for the following purposes: 1. Detection of re-occurring repaired fatal error conditions on the Link (PA_INIT loop). This kind of detection is useful if capabilities exchanged between local and peer permit a potential operation at a higher M-PHY Gear, but the physical interconnect between local and peer Device does not, or, after Line quality degradation, no longer satisfies channel characteristics. 2. Detection of degraded inbound or outbound Link quality, to allow an Application to issue an ADAPT sequence for a Link running in HS-G4 or higher HS Gears. This kind of detection is used to monitor a slowly degrading Link quality, e.g., one being affected by temperature and voltage variations, against the expected M-PHY bit error rate. Userspace can configure and enable UniPro QoS via UniPro QoS Attributes (via UFS BSG) and get notified by dme_qos_notification without polling UniPro QoS Status attribute. The dme_qos_notification attribute is a bitfield with the following bit assignments: Bit Description === ====================================== 0 DME QoS Monitor has been reset by host 1 QoS from TX is detected 2 QoS from RX is detected 3 QoS from PA_INIT is detected Signed-off-by: Can Guo <can.guo@oss.qualcomm.com> Reviewed-by: Bart Van Assche <bvanassche@acm.org> Reviewed-by: Peter Wang <peter.wang@mediatek.com> Link: https://patch.msgid.link/20260305110856.959211-2-can.guo@oss.qualcomm.com Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'tools/lib/python')
0 files changed, 0 insertions, 0 deletions